Page MenuHome

Fluid: No Obstacle after resume baking
Closed, ResolvedPublic

Description

System Information
Operating system: Windows-10-10.0.17763-SP0 64 Bits
Graphics card: Intel(R) UHD Graphics 620 Intel 4.5.0 - Build 25.20.100.6793

Blender Version
Broken: version: 2.83 (sub 13), branch: master, commit date: 2020-04-13 17:13, hash: rBad317a5ffdcf
Worked: (newest version of Blender that worked as expected)

Short description of error
Mantaflow ignores obstacles when resuming the bakingprocess

Exact steps for others to reproduce the error
Create a fluidsim with an obstacle. pause the baking and resume ist. Mantaflow ignores the obstacle since the Point of resuming.

  • Open blend
  • hit Bake Data
  • hit at something like frame 25
  • hit Resume
  • let it bake till the end
  • inspect the bake --> particles start falling through the Collision Effector (Sphere) from the frame where bake was resumed...


Expected vs actual

Event Timeline

til ation (tilation) updated the task description. (Show Details)
Ankit Meel (ankitm) changed the task status from Needs Triage to Confirmed.EditedApr 15 2020, 11:27 AM

See the photos here:


a is the uninterrupted baking, b is interrupted at frame 8. So frame b9 b10 b11 ignore the sphere.
File + two cache folders: https://drive.google.com/file/d/1e_0l3d3H5dn8qt3lQtdn2TOJ8eJPmTQB/view?usp=sharing
both have the same name except that the uninterrupted cache folder has an extra 1 in the end.

This needs a sample file, we need to stop accepting these reports with incomplete information.

@Ankit Meel (ankitm) thanks for helping with triaging, but if you are to do the work from the report, we still need the basic information, a simple .blend file to reproduce the issue, and images attached to this task.
Files hosted externally are not valid.

@Philipp Oeser (lichtwerk) if this is confirmed, then again, I would expect the task description to have all the information required to reproduce this (e.g., the .blend)

Confirmed in today's builds (8cb10c124efe)

I had in fact created another task (T75851) before realizing it was a duplicate.

Closed that one, I report the reproduction steps here ↓


Exact steps for others to reproduce the error

Note: because of T75850 the order of operation here is fundamental to reproduce

  • Default file. (Activate X-Ray)
  • Default cube: Add: Fluid > Effector
  • Add Plane. Move up Z +2.
  • Add: Fluid > Flow > Type Liquid; Flow Source > Is Planar
  • Add new cube at origin. Scale up by 2.5.
  • Add: Fluid > Domain > Type Liquid
  • Cache type: Modular. Frame end: 10
  • Bake Data
    • The effector is correclty taken into account
  • Cache frame end: increase to 20
  • Resume
    • The effector is ignored from frame 11 onwards

Similarly to T75758, this issue should be resolved since cdc399a05537. So closing this report, thanks for reporting!